Description
The Pentair Nocchi DHI 2-40M (code 422-0240) is a horizontal multistage centrifugal pump in AISI 316 stainless steel, for 230v single-phase supply. It delivers up to 60 litres per minute, with 36 metres of head at 10 l/min and 17 metres at 60 l/min, from a 0.40 kW motor drawing 3.2 A. Suction and delivery are 1¼”. The pump weighs 11.0 kg and is 368 mm long.
The 2-40 is the entry model of the low-flow DHI 2 family, for small demands where you need steady pressure rather than volume: one or two outlets on an upper floor, a small washing system or a machine supply. If you need more pressure at the same flows, the DHI 2-60M adds about 10 metres at 40 l/min. If your demand is above 60 l/min, move to the DHI 4-30M, which gives the same 27 metres at 40 l/min but carries on to 120 l/min. The DHI 2-40T is the 400v three-phase version.
The pump body, impellers and shaft are AISI 316 stainless steel, the motor housing is die-cast aluminium, and the mechanical seal is carbon on ceramic with EPDM gaskets. The 2-pole motor runs at 2850 rpm, is IP55 rated and has Class F insulation. Suction and delivery are both 1¼” threaded connections, set at 90 degrees to each other. The pump is supplied as a bare pump and motor, without a pressure switch, vessel or controller.
Features
- Smallest and lightest DHI: 0.40 kW, 368 mm long, 11 kg
- 36 m at 10 l/min, 27 m at 40 l/min, up to 60 l/min
- 230v single-phase motor, 3.2 A
- AISI 316 stainless steel pump body, impellers and shaft
- Rated for clean water up to 90°C
- IP55 motor with Class F insulation, 2850 rpm
- 1¼” suction and delivery at 90 degrees
Applications
- Small booster sets for one or two outlets
- Washing systems and machine supplies at low flow
- Hot water transfer up to 90°C
Performance
| Flow (l/min) | 10 | 20 | 30 | 40 | 50 | 60 |
|---|---|---|---|---|---|---|
| Head (m) | 36 | 34 | 31 | 27 | 22 | 17 |
The DHI is for clean water without suspended solids or abrasive material, up to 90°C, with a maximum operating pressure of 6 bar at 90°C. It is not self-priming: fill the casing and suction pipe before starting, and never run it dry. On 230v single-phase, connect it through a suitable isolator with fuses and motor protection, as Pentair’s manual requires. For drinking water boosting in the UK, draw from a break tank or cistern rather than connecting straight to the mains supply pipe without your water supplier’s consent.

The Nocchi DHI range
| Model | Supply | Motor output P2 (kW) | Current (A) | Head at 40 l/min (m) | Highest listed head (m) | Max flow (l/min) |
|---|---|---|---|---|---|---|
| DHI 2-40M | 230v single-phase | 0.40 | 3.2 | 27 | 36 | 60 |
| DHI 2-60M | 230v single-phase | 0.60 | 4.1 | 37 | 53 | 60 |
| DHI 2-70M | 230v single-phase | 0.78 | 5.2 | 44 | 63 | 60 |
| DHI 4-30M | 230v single-phase | 0.50 | 3.6 | 27 | 27 | 120 |
| DHI 4-40M | 230v single-phase | 0.70 | 4.4 | 35 | 35 | 120 |
| DHI 4-50M | 230v single-phase | 0.90 | 5.8 | 44 | 44 | 120 |
| DHI 2-40T | 400v three-phase | 0.40 | 1.4 | 27 | 36 | 60 |
| DHI 2-60T | 400v three-phase | 0.60 | 1.8 | 37 | 53 | 60 |
| DHI 2-70T | 400v three-phase | 0.78 | 1.8 | 44 | 63 | 60 |
| DHI 4-30T | 400v three-phase | 0.50 | 1.7 | 27 | 27 | 120 |
| DHI 4-40T | 400v three-phase | 0.70 | 2.0 | 35 | 35 | 120 |
| DHI 4-50T | 400v three-phase | 0.90 | 2.0 | 44 | 44 | 120 |
Figures are from Pentair’s DHI datasheet. See the Nocchi DHI multistage pump range page for help choosing between models and answers to common questions.











Reviews
There are no reviews yet.