Description
The JS RST-75H 400v (code 012-077) is a three-phase top outlet submersible drainage pump for clean and dirty water. It delivers up to 1,310 litres per minute and a maximum head of 41.5 metres from a 7.5 kW motor, through a 4″ outlet, on a 400v three-phase supply. This is the high head version of the RST-75 and the strongest lifter in the whole RST range, with a maximum head of 41.5 metres.
It is a manual pump with no float switch, so it runs whenever power is applied. For automatic operation it is wired through a three-phase control panel with level floats; see our pump controls. In the same range, the JS RST-75 is the standard version, 1,720 l/min to 32 m, and the JS RST-55H is the 5.5 kW high head model, 1,155 l/min to 35 m.
Like the rest of the RST range, it has a stainless steel outer case, shaft and motor case, with a cast iron lower motor bearing and seal housing, motor top cover and volute. Twin mechanical seals (carbon ceramic and silicon carbide) run in a lubricated oil chamber. Water is drawn in through the strainer at the base and discharged through the outlet on top, and the pump is supplied with 10 metres of power cable. JS’s datasheet for the 2.2 kW and larger models adds a double case that sends the pumped water around the motor for cooling, thermal overload protection in the motor, and a stator that can be rewound without being removed from the motor frame.
Features
- 7.5 kW motor, 400v three-phase
- Up to 1,310 l/min and 41.5 m head
- High head hydraulics for extra lift
- 4″ top outlet
- Twin mechanical seals (carbon ceramic and silicon carbide) in a lubricated oil chamber
- Stainless steel outer case, shaft and motor case with cast iron volute and top cover
- Designed by JS for continuous duty
- Thermal overload protection in the motor
- Manual operation, no float switch
- 10 metres of power cable
Applications
- Pumping to a high discharge point, such as out of a deep excavation
- Long delivery hose or pipe runs where friction adds to the head
- Water transfer up to raised tanks or ponds
- Water features that need height as well as volume
The RST range is for clean and dirty water. It is not a sewage pump and is not designed for raw sewage, rag, fibrous material, sludge, oil or chemicals: for sewage on a 400v supply, see the JST SV sewage vortex pumps. It needs a 400v three-phase supply, should stand upright (JS advises these pumps must not be installed lying on their side), and, like any standard submersible, it stops drawing once the water falls below the intake.

The JS RST 400v range
| Model | Type | Outlet | Max Flow (l/min) | Max Head (m) | Motor (kW) | Code |
|---|---|---|---|---|---|---|
| RST-6 | Standard | 2″ | 280 | 11 | 0.55 | 012-006 |
| RST-8 | Standard | 2″ | 345 | 15 | 0.75 | 012-008 |
| RST-15 | Standard | 2″ | 435 | 22 | 1.5 | 012-015 |
| RST-22 | Standard | 3″ | 850 | 20 | 2.2 | 012-022 |
| RST-37 | Standard | 3″ or 4″ | 1,170 | 23 | 3.7 | 012-037 |
| RST-55 | Standard | 4″ | 1,670 | 29 | 5.5 | 012-055 |
| RST-75 | Standard | 4″ | 1,720 | 32 | 7.5 | 012-075 |
| RST-22H | High head | 2″ or 3″ | 765 | 23 | 2.2 | 012-024 |
| RST-37H | High head | 2″ or 3″ | 920 | 29 | 3.7 | 012-039 |
| RST-55H | High head | 3″ | 1,155 | 35 | 5.5 | 012-059 |
| RST-75H | High head | 4″ | 1,310 | 41.5 | 7.5 | 012-077 |
Flow and head are the maximums read from the JS performance curves above. For the single-phase 110v and 230v equivalent, see the JS RS top outlet range. See the JS RST top outlet range page for help choosing between models and answers to common questions.





Reviews
There are no reviews yet.