Description
The Pentax DCT 560 400v (code 020-642) is a heavy-duty submersible centrifugal drainage pump for high head work. It reaches a maximum head of 38.7 metres and delivers up to 850 litres per minute from a 4 kW (5.5 hp) motor, through a DN50 flanged outlet, running on 400v three-phase at 10.7 A.
The DCT 560 shares its frame and DN50 flange with the Pentax DCT 410 400v but adds a 4 kW motor. It gives 33.9 metres at 200 l/min, 28.3 metres at 400 l/min and 20.9 metres at 600 l/min, about 4 to 5 metres more than the DCT 410 at each point, and reaches 850 l/min at low head. For heads above 40 metres, the Pentax DCT 750 400v steps up to a DN65 outlet.
Like every pump in the Pentax DC range, it has a cast iron pump body and impeller, an AISI 304 stainless steel motor shaft and a double mechanical seal in an oil chamber, with silicon carbide faces on the pump side and ceramic and graphite on the motor side. The two-pole motor has class F insulation and IPX8 protection, comes with 10 metres of power cable, and Pentax rates it for submersion to 20 metres in liquid from 0 to 40 °C. The pump stands freely on a galvanised base with a side outlet.
The DN50 outlet is flanged. A matching DN50 counter flange is needed to connect pipework; call us and we will confirm the right one.
Features
- 4 kW (5.5 hp) motor, 400v three-phase, 10.7 A
- Maximum head 38.7 m, maximum flow 850 l/min
- DN50 flanged side outlet
- Cast iron pump body and impeller
- Double mechanical seal in an oil chamber
- 10 m power cable
Applications
- Very deep pits, shafts and underground plant rooms
- Pumping drainage water up several storeys or a steep site
- Long pipe runs where friction losses add significant head
- Industrial and civil drainage with a three-phase supply
Suitable for clean and dirty water with solids up to 10 mm, up to 40 °C. Not designed for sewage, rag or fibrous material, or for flammable or corrosive liquids, and never run it dry. The pump has no float switch; for automatic operation, wire it through a starter or control panel with overload protection and level float switches. See our float switches and pump controls.

The Pentax DC range
| Model | Voltage | Outlet | Max Flow (l/min) | Max Head (m) | Motor (kW) | Current (A) | Weight (kg) | Code |
|---|---|---|---|---|---|---|---|---|
| DC 160 | 230v | 2″ G | 600 | 18.9 | 1.1 | 13.8 | 37 | 020-630 |
| DC 210 | 230v | 2″ G | 650 | 23.0 | 1.5 | 16.5 | 37.5 | 020-632 |
| DCT 160 | 400v | 2″ G | 600 | 18.9 | 1.1 | 4.8 | 37 | 020-634 |
| DCT 210 | 400v | 2″ G | 650 | 23.0 | 1.5 | 5.9 | 37.5 | 020-636 |
| DCT 310 | 400v | 2″ G | 700 | 26.4 | 2.2 | 6.9 | 37 | 020-638 |
| DCT 410 | 400v | DN50 flange | 800 | 33.8 | 3 | 8.9 | 60.5 | 020-640 |
| DCT 560 | 400v | DN50 flange | 850 | 38.7 | 4 | 10.7 | 63.5 | 020-642 |
| DCT 750 | 400v | DN65 flange | 900 | 47.6 | 5.5 | 15.3 | 91 | 020-644 |
| DCT 1000 | 400v | DN65 flange | 900 | 55.1 | 7.5 | 17.5 | 93.5 | 020-646 |
Flow and head are Pentax’s published 50 Hz maximums; max head is at zero flow. See the Pentax DC range page for help choosing a model and answers to common questions.










Reviews