Description
The Pentair Jung Drenox 80/7 Manual 110v (code 555-001) is the smallest Drenox stainless steel submersible drainage pump, supplied for 110v site transformers. It has a 0.2 kW motor and a 1¼” outlet, and Jung rates the 80/7 to pump down to just 3 mm of water once it is primed. Jung Pumpen’s table gives 57 litres per minute at 2 metres of head, 43 l/min at 3 m and 17 l/min at 5 m, with the curve ending at 6 m. Jung publishes these figures for the 230v 80/7 and does not list separate figures for the 110v version.
This is the manual version, so it runs whenever the power is on: you stay with it, or switch it from a separate float switch or panel. The Drenox 80/7 Automatic 110v adds a float switch on the pump, and the Drenox 80/7 Manual 230v is the mains version.
Like every Drenox, the pump is made from AISI 304 stainless steel: pump housing, impeller and motor casing. The double seal is NBR rubber with a sand guard V-ring running in an oil chamber, and a heat exchange chamber cools the motor, so the pump can run for long periods without being fully submerged. It comes with 10 metres of cable and an elbow hose fitting for 32 mm hose on the 1¼” outlet.
Features
- All AISI 304 stainless steel construction
- Pumps down to 3 mm once primed
- 0.2 kW motor for a 110v site supply
- 1¼” outlet with elbow fitting for 32 mm hose
- Double NBR seal with sand guard, in an oil chamber
- Manual operation; 10 m of cable
- Weighs 5.7 kg
Applications
- Clearing standing water from floors, slabs and shallow pits on site
- Lift pits, chambers and excavations with low inflow
- Emptying tanks on 110v supplies
For clear water, partly dirty water and non-aggressive liquids up to 40°C, with solids no larger than 3 mm. It must never run completely dry, and it is not suitable for sewage, sludge, leaves or rag, or for flammable or dangerous liquids. For dirtier water with soft solids, see the Jung Omnia vortex pumps; for sewage, the Jung Nocchi Priox range.


The Drenox range
| Model | Supply | Operation | Motor P2 (kW) | Current (A) | Flow at 3 m (l/min) | Flow at 5 m (l/min) | Free passage (mm) | Pumps down to (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 80/7 Manual 110v | 110v | Manual | 0.2 | not published | 43 | 17 | 3 | 3 | 5.7 |
| 80/7 Automatic 110v | 110v | Float switch | 0.2 | not published | 43 | 17 | 3 | 100 (float) | 5.7 |
| 80/7 Manual 230v | 230v | Manual | 0.2 | 1.3 | 43 | 17 | 3 | 3 | 5.7 |
| 80/7 Automatic 230v | 230v | Float switch | 0.2 | 1.3 | 43 | 17 | 3 | 100 (float) | 5.7 |
| 160/8 Manual 230v | 230v | Manual | 0.4 | 2.4 | 103 | 60 | 6 | 35 | 6.5 |
| 160/8 Automatic 230v | 230v | Float switch | 0.4 | 2.4 | 103 | 60 | 6 | 107 (float) | 6.5 |
| 250/10 Manual 230v | 230v | Manual | 0.55 | 4.5 | 183 | 130 | 6 | 35 | 7.0 |
| 250/10 Automatic 230v | 230v | Float switch | 0.55 | 4.5 | 183 | 130 | 6 | 111 (float) | 7.0 |
| 350/12 Manual 230v | 230v | Manual | 0.8 | 5.1 | 250 | 200 | 6 | 35 | 8.5 |
| 350/12 Automatic 230v | 230v | Float switch | 0.8 | 5.1 | 250 | 200 | 6 | 111 (float) | 8.5 |
| 350/12 T Manual 400v | 400v 3-phase | Manual | 0.8 | 2.0 | 250 | 200 | 6 | 35 | 8.5 |
Flow is converted from Jung Pumpen’s published performance tables for the 230v and 400v pumps. Jung does not publish separate figures for the 110v 80/7. Automatic versions stop at the float switch-off level shown. See the Pentair Jung Drenox drainage pump range page for help choosing and answers to common questions.