Description
The Pentair Jung Drenox 350/12 T Manual 400v (code 555-029, Jung N1031110) is the three-phase version of the largest Drenox stainless steel submersible drainage pump. It has a 0.8 kW motor (1.2 kW absorbed) drawing 2.0 A on a 400v three-phase supply and a 1¼” outlet, and passes solids up to 6 mm. Jung Pumpen’s table gives 275 litres per minute at 2 metres of head, 250 l/min at 3 m, 200 l/min at 5 m and 108 l/min at 8 m, with 38 l/min still at 10 m.
Hydraulically it matches the single-phase Drenox 350/12 Manual 230v, so choose it where a 400v supply or control panel is already in place, in a plant room or industrial unit for example. Unlike the single-phase models it has no thermal overload in the motor, so it must be wired through a motor protection circuit breaker or a contactor with a thermal overload relay set to the motor’s rating. It is manual only: for automatic running, switch it from a float switch through a suitable panel.
Like every Drenox, it is made entirely from AISI 304 stainless steel: pump housing, impeller and motor casing. The stainless steel shaft has ceramic inserts where the seal wears, the double seal is NBR rubber with a sand guard V-ring running in an oil chamber, and the ball bearings are self-lubricating. A heat exchange chamber cools the motor, so the pump can run for long periods without being fully submerged. The motor is IP68 with Class F insulation and runs at 2850 rpm. The pump is rated for immersion to 7 metres and water up to 40°C, and comes with 10 metres of H07RN-F cable and an elbow hose fitting for 32 mm hose on the 1¼” outlet.
Features
- All AISI 304 stainless steel construction
- 0.8 kW motor, 400v three-phase, 2.0 A
- About 250 l/min at 3 m and 200 l/min at 5 m
- 6 mm free passage; pumps down to about 35 mm
- 1¼” outlet with elbow fitting for 32 mm hose
- Manual operation; 10 m of cable; 8.5 kg
Applications
- Plant room and industrial unit drainage on 400v
- Sumps and tanks run from a three-phase control panel
- Light industrial drainage and water transfer
For clear water, partly dirty water and non-aggressive liquids up to 40°C, with solids no larger than 6 mm, such as silt and fine grit. It must never run completely dry, and it is not suitable for sewage, sludge, leaves or rag, or for flammable or dangerous liquids. For dirtier water with soft solids, see the Jung Omnia vortex pumps; for sewage, the Jung Nocchi Priox range.


The Drenox range
| Model | Supply | Operation | Motor P2 (kW) | Current (A) | Flow at 3 m (l/min) | Flow at 5 m (l/min) | Free passage (mm) | Pumps down to (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|---|
| 80/7 Manual 110v | 110v | Manual | 0.2 | not published | 43 | 17 | 3 | 3 | 5.7 |
| 80/7 Automatic 110v | 110v | Float switch | 0.2 | not published | 43 | 17 | 3 | 100 (float) | 5.7 |
| 80/7 Manual 230v | 230v | Manual | 0.2 | 1.3 | 43 | 17 | 3 | 3 | 5.7 |
| 80/7 Automatic 230v | 230v | Float switch | 0.2 | 1.3 | 43 | 17 | 3 | 100 (float) | 5.7 |
| 160/8 Manual 230v | 230v | Manual | 0.4 | 2.4 | 103 | 60 | 6 | 35 | 6.5 |
| 160/8 Automatic 230v | 230v | Float switch | 0.4 | 2.4 | 103 | 60 | 6 | 107 (float) | 6.5 |
| 250/10 Manual 230v | 230v | Manual | 0.55 | 4.5 | 183 | 130 | 6 | 35 | 7.0 |
| 250/10 Automatic 230v | 230v | Float switch | 0.55 | 4.5 | 183 | 130 | 6 | 111 (float) | 7.0 |
| 350/12 Manual 230v | 230v | Manual | 0.8 | 5.1 | 250 | 200 | 6 | 35 | 8.5 |
| 350/12 Automatic 230v | 230v | Float switch | 0.8 | 5.1 | 250 | 200 | 6 | 111 (float) | 8.5 |
| 350/12 T Manual 400v | 400v 3-phase | Manual | 0.8 | 2.0 | 250 | 200 | 6 | 35 | 8.5 |
Flow is converted from Jung Pumpen’s published performance tables for the 230v and 400v pumps. Jung does not publish separate figures for the 110v 80/7. Automatic versions stop at the float switch-off level shown. See the Pentair Jung Drenox drainage pump range page for help choosing and answers to common questions.





Reviews