JST KZN-H & KZN-L Industrial Heavy Duty Pumps 400v
The JST KZN-H and KZN-L are the high head and high flow versions of JS Pumps’ KZN agitator slurry pump. They share the standard KZN’s motor sizes and heavy duty build, but each has a pump end matched to a different job: the H models lift slurry higher, and the L models move more of it over a shorter lift. There are five three-phase 400v models: the KZN-H at 5.5, 7.5 and 11 kW, and the KZN-L at 15 and 22 kW.
Like every KZN, they have a high chrome iron impeller, agitator and suction cover (wear plate), with the agitator stirring settled sand and silt back into suspension at the inlet. Double silicon carbide mechanical seals run in an oil chamber behind a lip seal and shaft sleeve, the top outlet and water jacket use the pumped liquid to cool the motor, and the 4-pole motors run at 1,500 rpm on 50 Hz with a built-in overload protector.
KZN-H or KZN-L: which do you need?
KZN-H (high head) models give up some flow to reach greater heights. The JST-110 KZN-H, for example, reaches 29 m against 22 m for the standard JST-110 KZN, but its maximum flow is 2,585 l/min rather than 4,135 l/min, through a 4-inch outlet instead of a 6-inch. Choose an H model for deep excavations, shafts and long or steep discharge runs.
KZN-L (high flow) models are built for volume. The JST-150 KZN-L delivers up to 5,910 l/min, against 3,305 l/min for the standard JST-150 KZN, with maximum head falling from 32 m to 23.5 m. The JST-220 KZN-L has an 8-inch outlet; on the JS curves its maximum flow matches the standard JST-220 KZN, while its maximum head is lower, so compare both curves at your duty point before choosing.
To pick a size, work out your total head (vertical lift plus hose friction) and read the flow each curve gives at that head. If your duty sits comfortably within the standard range, the standard JST KZN slurry pumps may suit you better.
| Model | Version | Outlet | Motor (kW) | Max Flow (l/min) | Max Head (m) | Max Solids (mm) | Standard KZN equivalent (l/min / m) |
|---|---|---|---|---|---|---|---|
| JST-55 KZN-H | High head | 3″ | 5.5 | 2,205 | 20.5 | 25 | JST-55 KZN: 2,430 / 19 |
| JST-75 KZN-H | High head | 4″ | 7.5 | 2,345 | 23.5 | 25 | JST-75 KZN: 2,570 / 20.5 |
| JST-110 KZN-H | High head | 4″ | 11 | 2,585 | 29 | 35 | JST-110 KZN: 4,135 / 22 |
| JST-150 KZN-L | High flow | 6″ | 15 | 5,910 | 23.5 | 35 | JST-150 KZN: 3,305 / 32 |
| JST-220 KZN-L | High flow | 8″ | 22 | 5,960 | 29 | 35 | JST-220 KZN: 5,960 / 33.5 |
All models are 400v three-phase. Flow and head are maximums from the JS Pumps performance curves shown on the product pages; click through to any model for its full details.
Showing all 5 results
- Heavy duty high head submersible slurry pump with a built-in high chrome agitator, 3" outlet, 400v three-phase. Up to ...Read More
Flow Rate (l/min)
1000 l/min +Max Head (m)
11- 20mVoltage
400v£3,107.89 +VAT - Heavy duty high head submersible slurry pump with a built-in high chrome agitator, 4" outlet, 400v three-phase. Up to ...Read More
Flow Rate (l/min)
1000 l/min +Max Head (m)
21 - 30mVoltage
400v£3,532.93 +VAT - Heavy duty high head submersible slurry pump with a built-in high chrome agitator, 4" outlet, 400v three-phase. Up to ...Read More
Flow Rate (l/min)
1000 l/min +Max Head (m)
21 - 30mVoltage
400v£4,636.24 +VAT - Heavy duty high flow submersible slurry pump with a built-in high chrome agitator, 6" outlet, 400v three-phase. Up to ...Read More
Flow Rate (l/min)
1000 l/min +Max Head (m)
21 - 30mVoltage
400v£6,002.44 +VAT - Heavy duty high flow submersible slurry pump with a built-in high chrome agitator, 8" outlet, 400v three-phase. Up to ...Read More
Flow Rate (l/min)
1000 l/min +Max Head (m)
21 - 30mVoltage
400v£9,647.02 +VAT
Where KZN-H and KZN-L Pumps Fit
The high head KZN-H models suit jobs where muddy water has a long way to climb: deep basement and foundation excavations, shafts and tunnels, quarry pits discharging up to a settling lagoon, or any site where the discharge point is far from the pump. The JST-55 and JST-110 KZN-H also have smaller outlets than their standard equivalents, so they run on smaller, lighter hose.
The high flow KZN-L models are for shifting large volumes of silty water over a short lift, such as emptying lagoons, settling ponds and flooded pits, or clearing water and silt from river and culvert works. With 6 and 8-inch outlets, hose size matters: undersized hose throws away the flow you are paying for, as our guide to discharge pipe sizing explains. For either version, work out the duty point first using our guide to pump head and flow rate, and remember that published curves are for water, so thick slurry needs a margin.
If you need more lift than the KZN-H offers, look at the agitator pumps in the JST KB range. For water without heavy solids, a JST or JST-H drainage pump is the lighter, less expensive option. You can also browse all our dewatering pumps.
Frequently Asked Questions
What do the H and L suffixes mean on JS KZN pumps?
H stands for high head and L for high flow. Both use the same motor ratings as the standard KZN, with a different pump end: an H model trades flow for extra lift, and an L model trades lift for extra flow.
Which sizes come as KZN-H and KZN-L?
The KZN-H is available at 5.5 kW (JST-55), 7.5 kW (JST-75) and 11 kW (JST-110). The KZN-L is available at 15 kW (JST-150) and 22 kW (JST-220). The 3.7 kW JST-37 comes only as a standard KZN.
Will a high head model give me more water on my site?
Only when your total head is high. Above the standard model’s maximum head, only the H version will deliver at all; below it, compare the two curves at your duty point, because the standard model has the higher maximum flow. Not sure of your total head? Call us with the lift and hose length.
Why does the JST-55 KZN-H have a smaller outlet than the JST-55 KZN?
The H version moves less water to a greater height, so it uses a 3-inch outlet where the standard JST-55 KZN has a 4-inch. Use 3-inch hose, or larger on a long run, but never smaller than the outlet.
Can the H and L versions handle the same solids as the standard KZN?
Yes, they share the agitator and high chrome iron wear parts. The JST-55 and JST-75 KZN-H pass solids up to 25 mm, and the JST-110 KZN-H, JST-150 KZN-L and JST-220 KZN-L up to 35 mm. Like the standard KZN, they are slurry pumps for sand, silt and sludge rather than sewage pumps for rag and fibres.
What power supply do they need?
All five are 400v three-phase pumps and need a suitable starter or control panel with motor protection sized to the pump’s full load current.
For help choosing between a KZN-H, a KZN-L and a standard KZN for your job, call the AES Rewinds team on 01252 515169 or email sales@aesrewinds.com. You can also browse the full JS Pumps range or all industrial water pumps.
Need help? Got a question?
Give us a call on 01252 515169, email or Fill out the form below and we will be in touch.