The Oreal CDI-H27 12v (code 050-560) is a battery-powered AdBlue transfer pump for vans, pickups, plant and anything else with a 12v electrical system. It delivers up to 30 litres per minute and a maximum head of 10 metres from a 0.2 kW DC motor drawing 10 amps, through a 1″ outlet. It comes with 1.5 metres of power cable and battery clamps, so you can clip it onto a vehicle battery and fill straight from a drum or IBC.
If your truck or machine runs on 24v, the CDI-H27 24v is the same pump with a 24v motor drawing half the current. For a fixed filling point with a mains socket, the CDI-H27 230v moves up to 40 litres per minute.
Every CDI-H27 is a five-chamber positive displacement diaphragm pump with a bypass built into the pump body. A diaphragm pump moves a fixed volume with each stroke, so it is self-priming and can lift AdBlue up to 2 metres from a container below the pump. The bypass lets the pump run for short periods against a closed delivery, such as a closed nozzle, though Oreal limits this to 3 minutes at a time. Every model has an on/off switch on the unit, an IP54 rating and a 1″ outlet, and comes with hose tails to suit 1″ and ¾” hose.
Features
- 12v DC, 0.2 kW motor, 10 A
- Up to 30 l/min and 10 m head
- Self-priming, up to 2 m suction lift
- Five-chamber positive displacement diaphragm pump with built-in bypass
- On/off switch on the pump
- 1.5 m power cable with battery clamps
- 1″ outlet, hose tails for 1″ and ¾” hose supplied
- IP54
- 130 x 130 x 292 mm, 4.8 kg
Applications
- Topping up AdBlue in vans, pickups and 12v plant from a drum or IBC
- Mobile filling from a container carried on a service vehicle
- Decanting AdBlue into smaller containers where no mains supply is available
The 12v model is rated for roughly 20 minutes of running in every hour: Oreal’s manual says to switch off after 20 minutes and let the motor cool for 20 minutes. It suits top-ups and occasional transfers rather than long, continuous pumping.
Designed for AdBlue (AUS 32, also sold as DEF) only. Not suitable for petrol, or for any flammable or explosive liquid, and not for liquids carrying suspended particles, fibres or abrasive material. For diesel and gas oil, use a fuel pump such as the GMP RED diesel transfer pumps. Do not run the pump dry for more than 10 minutes, and use hoses and fittings made for AdBlue: it attacks copper, brass, galvanised steel and plain carbon steel. If the pump will stand unused for a long period, rinse it through with clean water and store it dry, because AdBlue left in the pump body crystallises.
Mount the pump close to the container, keep the suction pipe no longer than 2 metres vertically and at least the size of the inlet, and make every joint airtight. Oreal recommends a filter on the suction inlet and a semi-rigid suction hose. Our guides to self-priming pumps and suction lift and NPSH explain how to get reliable priming.
The Oreal CDI-H27 range
| Model | Code | Supply | Motor (kW) | Current (A) | Max Flow (l/min) | Max Head (m) | H x W x L (mm) | Weight (kg) |
|---|---|---|---|---|---|---|---|---|
| CDI-H27 12v | 050-560 | 12v DC | 0.2 | 10 | 30 | 10 | 130 x 130 x 292 | 4.8 |
| CDI-H27 24v | 050-562 | 24v DC | 0.2 | 5 | 30 | 10 | 130 x 130 x 292 | 4.8 |
| CDI-H27 230v | 050-561 | 230v single-phase | 0.37 | 2 | 40 | 10 | 160 x 130 x 295 | 6.2 |
Flow and head are Oreal’s published maximums. All models have a 1″ outlet, 2 m maximum suction lift and IP54 rating.