AES Rewinds Logo

Free Delivery over £200

Shop 24 Hours a day

KOSHIN KTH Engine Driven Compact Trash Pumps

Koshin KTH trash pumps are compact petrol engine pumps built to move dirty water that carries stones, grit and debris. Koshin, the Japanese pump maker, fits each one with a four-stroke Honda engine and a hi-chrome impeller turning inside a spheroidal graphite iron volute, sealed by a silicon carbide mechanical seal. That combination is chosen to stand up to the abrasive water found on building sites, in excavations and after flooding.

The KTH is Koshin’s trash pump range, so it passes far larger solids than a semi-trash pump: up to 20 mm on the 2″ model and 27 mm on the 3″ and 4″ models. Each pump draws water from as much as 8 metres below it once the casing has been filled, and comes with a strainer, two hose couplings, three hose bands and an engine tool set.

Choosing the right KTH model

The number in each model name is the connection size in millimetres: 50 for 2″, 80 for 3″ and 100 for 4″. The KTH-50X with a Honda GX160 is the lightest and easiest to move, and suits smaller excavations and trench dewatering. The KTH-80S with a Honda GX270 moves twice the water and passes 27 mm solids, which makes it a strong all-round site pump.

For the largest volumes, the KTH-100S with a Honda GX390 delivers up to 2,050 litres per minute with 30 metres of head. Koshin designed the S models for quick servicing: the cleanout cover comes off without disconnecting the hoses, and the impeller has a hexagon boss so it is easier to fit and remove.

Solids, fuel and weight

Pick a model whose solids rating is larger than the debris you expect, and plan for a refuel roughly every two hours. At 47 to 79.5 kg, every KTH is a job for two people or a lifting aid.

ModelConnectionsEngineMax flow (l/min)Max head (m)Max solids (mm)Fuel tank (L)Run time per tankNet weight (kg)
KTH-50X2″Honda GX16070030203.1About 2.2 hours47
KTH-80S3″Honda GX2701,45027275.3About 2 hours65
KTH-100S4″Honda GX3902,05030276.1About 2 hours79.5

Flow and head are Koshin’s maximum figures: flow is measured with no head, and head is the height at which flow stops. Click through to any model for full specifications.

Showing all 3 results

Where to Use Koshin KTH Trash Pumps

A KTH pump earns its keep wherever water is mixed with mud, sand and stones: dewatering foundations, trenches and excavations, emptying flooded basements, cellars and car parks, and clearing ponds, ditches and lagoons. With its own fuel on board, the pump works where there is no power supply, and the large solids passage means it keeps running where a clear water pump would block or wear quickly.

Use the KTH for dirty water rather than thick sludge. Fit a suction hose that will not collapse, keep the strainer on the end, and set the pump as close to the water as is safe, because every metre of suction lift and every length of hose cuts the flow. Our guide to flood pumps and the article on what a dirty water pump is explain how trash pumps compare with other options, and the self-priming pumps guide covers suction lift and priming.

If the water carries only fine silt and small grit, the Koshin STH semi-trash pumps are lighter and pass solids up to 9 mm. For clean water transfer and irrigation, choose the Koshin SEH Honda engine pumps. Where mains power is available on site, the GMP electric surface trash pumps avoid the need for fuel.

Frequently Asked Questions

What is a trash pump?

A trash pump is a portable self-priming pump with a wide impeller passage, built to move water containing stones, leaves and other debris without blocking. Koshin rates the KTH range to pass solids up to 20 mm on the 2″ model and 27 mm on the 3″ and 4″ models.

What is the difference between Koshin KTH and STH pumps?

The STH is a semi-trash pump for muddy water with small solids, up to 9 mm. The KTH is a full trash pump with a hi-chrome impeller that passes solids up to 27 mm, and it uses larger Honda engines. If the water carries gravel and debris, choose the KTH.

Can a KTH pump be used for sewage?

Koshin lists construction, irrigation and shallow well water supply as applications and does not list sewage. For raw sewage and toilet waste, use a pump designed for it; our guide on how sewage pumps work and how to choose one explains the options.

How do I clear a blockage?

Stop the engine, then remove the cleanout cover and clear the impeller and volute. On the KTH-80S and KTH-100S the cover comes off without disconnecting the hoses, and its handles can be fitted vertically or horizontally to suit the site.

Does the pump need priming?

Yes, the first time. Fill the casing with water through the filler before you start the engine; the pump then draws water up the suction hose by itself, from as much as 8 metres below. Never run it dry, because the mechanical seal relies on the water for cooling.

Are hoses included?

No. Koshin supplies each KTH with a strainer, two hose couplings, three hose bands and an engine tool set, so you add suction and delivery hose to suit the connection size.

For help choosing a trash pump, call the AES Rewinds team on 01252 515169 or email sales@aesrewinds.com. You can also browse all our petrol engine water pumps or the wider range of dirty water pumps.

Need help? Got a question?

Give us a call on 01252 515169, email or Fill out the form below and we will be in touch.